Client |
Description |
City of San Bruno
Mr. Barry Timko
Water Services Superintendent
650-877-8863
|
Assess
the condition of the coating and the extent of
corrosion damage to a 400,000 gallon pre-stressed
water storage tank. This inspection consisted
of a visual inspection of the interior and exterior
surfaces of the tank, conducting ultrasonic thickness
measurements of the floor plates and shell plates,
and testing the coating integrity and coating
thickness. Recommendations for rehabilitation
were provided. |
North Coast County Water Agency
Pacifica, CA
Mr. George Kanakaris
General Manager
650-355-3462 |
Conducted
a coating and corrosion evaluation of 12 steel
water storage tanks ranging in size from 5-million
gallons to 250,000 gallons. This inspection consisted
of conducting a detailed coating evaluation as
well as determining the degree and extent of any
corrosion damage. Provided recommendations for
rehabilitation of the twelve tanks and prepared
a detailed cost estimate for the repair of each
tank. |
Diablo Water District
Oakley, CA
Mr. Mike Yeraka
General Manager
925-625-6159 |
Designed
a cathodic protection system for a 2.5-million
gallon steel water storage tank. The cathodic
protection system consisted of a sacrificial type
of protection system utilizing magnesium anodes.
Assisted the District in the bidding process,
provided on-site inspection services during system
installation and energized and adjusted the system
following completion of the installation. |
 |
|